AEET Energy Group GmbH

Your Wholesaler for Europe

HOTLINE

+49 (0) 5382 - 955 979 - 0

Bild 01

AEET-Engineering by Elysator

easy – matching – sustainable

Bild 02

Technical water for more efficiency

to the Elysator products

››
Bild 03

Safe heating water to standard

to the PUROTAP products

››
Bild 04

For the energy-efficient heating

to the SANOL products

››
Bild 05

no rust - no lime - no gas

to the SorbOx products

››

SANOMAT 20 pro

SANOL H-15 and the pulsating change-rinsing-device SANOMAT 20 are exactly at this point and make residue-free rinsing easier. Without such rinsing before using cleaned water, you will never remove all sludge accumulation and blockages in the heating circuit. Such investment in the safety and life span of a heating system would be unfortunately almost meaningless without basic cleaning. Although corrosion makes no small degree of damage potential for a heating system, but it is far from being the only source of damage.

SANOMAT 20 pro & data sheets



Quick contact

Do you have questions about our products? We are available by email or telephone.
Or get in touch with us.

AEET Energy Group GmbH
Schwarzer Weg 5
D-37581 Bad Gandersheim

Telephone: 05382 - 955 979 - 0
Telefax: 05382 - 955 979 - 9

E-Mail: info@aeet-service.com

SANOMAT 20 pro

Each water system (heating, solar or cooling system) needs to be cleaned prior to final filling with treated water. This is especially true for older and refurbished systems. In this process, foreign materials (eg drawing greases, corrosion residue, solder, flux and welding agent) are removed from the system. However, even by a physical purging according to DIN 1988 (rinsing with speed, surge irrigation, reverse circulation, rinse with solid bodies) do not remove completely. Only the use of suitable cleaning agents (often based on fruit acids) reaches a residue-free removal of these substances.

The DIN EN 14336, still unheard by many professionals, provides that water systems must be rinsed. Unfortunately, the standard does not describe how that should be done. Most rinses are pointless, wasted time and even counterproductive, because the correct nominal width and arrangements of the rinse support a professional rinse is not permitted.

Plus, the cleaning agent must be removed completely, otherwise it can cause devastating effects to the treated filling water.

Clean the heating circuit in time

SANOL H-15 and the pulsating change-rinsing-device SANOMAT 20 are exactly at this point and make residue-free rinsing easier. Without such rinsing before using cleaned water, you will never remove all sludge accumulation and blockages in the heating circuit. Such investment in the safety and life span of a heating system would be unfortunately almost meaningless without basic cleaning. Although corrosion makes no small degree of damage potential for a heating system, but it is far from being the only source of damage.

Similar serious are sludge accumulations in heating circuits. The first signs of such are faults in the hydraulics of a heating system. This individual floor heating circuits, for example, are not getting warm enough. Nor can the thermostatic valves on the radiators and floor distributors serve no longer or only partially. As a result, the desired residential heat is no longer achieved.

If this progressive process is not countered, it will sooner or later indispensable lead to further damage. The next ordinary damages occur to the pump, mixing valves and heat exchangers. The corrosion particles located in the sludge accumulation scratch the metal interior surfaces repeatedly and thus produce more leaching by erosion. In particular, parts of soft metals such as copper and aluminum are particularly at risk. The amount of damage increases exponentially with the length and number of metal interior surfaces in a heating circuit.

Sludge accumulations also damage the central-heating boiler. Among the accumulating deposits it comes after some time to stress cracks in the material of the boiler. At these locations, the heating water evaporates repeatedly. The result are local corrosion attacks, gas formation and clearly audible, annoying noises.

SANOMAT 20

The exact pulse duration and pulse interval are simple and infinitely controllable. This also allows cleaning even very small pipes without residue. By combining the different purging modes, an efficient, timesaving rinsing of all standard heating systems is possible.

For an even shorter rinse time and an enhanced cleaning effect, we recommend that you put in the cleaning product SANOL H-15 (contact time 7-21 days), which is designed for exactly this purpose and this system before the system rinse. Especially in heavily silted heating systems and systems radiators, this approach ensures a thorough and easy cleaning system.

SANOL H-15

At this point Sanol H-15 is to be used at the latest. It finds a remedy at an early stage and provides a basic cleaned heating system. With SANOL H-15, the cleaning work is safer and cheaper. SANOL H-15 is a novel, highly effective cleaning agent from the market leader Elysator. It surrounds the particles of loose and easily adhering sludges. Thus they become more buoyant and can be flushed very easily. SANOL H-15 has to act a few days to develop to the maximum effect.

Unlike conventional detergents, SANOL H-15 is suitable for any system water quality and is completely safe for all system components. With its excellent complexing and dispersing action, SANOL H-15 removes all loose and slightly adherent deposits in heating and cooling systems. Including magnetite and rust sludge, construction dirt and remnants of conditioning chemicals. SANOL H-15 is compatible with all commonly used materials in heating and cooling systems as alloyed and unalloyed steels, cast metals, nonferrous metals, rubber and plastics.

SANOL H-15 can be added undiluted to the system water, 6 kg for 1,000 liters of water are sufficient.

High circulation rates and temperatures increase the effect of the product.

The necessary exposure time is at least 7 days. The product may be kept longer in the system.

During the exposure, all control valves the heating system must be open in, so that the product can be distributed in all parts of the plant. Afterwards, every individual heating circuit, radiator, convector etc. has to be rinsed with fresh water by opening and closing the valves. The central-heating boiler, heating water storages and any other pipeline need to be cleaned.

data sheet SANOMAT 20

The flushing device SANOMAT 20 was developed specifically for flushing of heating systems. The ability to reverse the flushing direction alternatively, a loosening of stubborn blockages is possible. Increases the system pressure of the flushing water, the flushing direction can be reversed by simply switching. By the added compressed air at certain intervals, the flushing impact optimizes. The exact pulse duration and pulse interval are simple and infinitely controllable, that allows ideal cleaning of even very small pipes. By combining the different purging modes, an efficient, timesaving rinsing of all standard heating systems is possible.

data sheet SANOL H-15

SANOL H-15 is a mild cleanser that is used to remove iron oxide mud and tying of residues of chemical inhibitors in water systems.

  • Mode of operation: SANOL H-15 removes iron oxide slurries, light iron oxide deposits and bonded thereto residues of chemical additives, which provides excellent complexing and dispersing properties
  • Practice: SANOL H-15 may be used with presence of usual materials by back chill arrangements, heat exchangers, ground heatings and conduits. With longer effect time galvanised parts can be easily attacked.
  • Qualities: H-15 SANOL is a clear, dark brown liquid with ammoniac smell.
  • Poisonous category: is not subject to the poison legislation
  • concentration: 1.2 g / ml
  • pH value: 9.5
  • Solidification point: 0 °C
  • Handling/Safety/Storage: Skin and eye contact should be avoided. When handling SANOL H-15 rubber gloves and safety goggles must be worn. Protect from frost. Do not mix the concentrate with acids or strong oxidizing agents.
  • Application instructions: SANOL H-15 is generally used as a 0.6% aqueous solution (approx. 6 kg of SANOL H-15 on 1000 l of water). High circulating rates and temperatures increase the effect of the product.
  • Required exposure time: From 7 to 21 days
  • Cleansing temperature: From 15 to 90 °C
  • German Institute for Standardization EN 14336 „heating systems in buildings – installation and acceptance of the hot-water heating systems; German version, 01-2005

5.5 Rinsing and cleaning of the arrangement

The heating system must be rinsed. A recommended method is to be found in appendix C

Remark: The cleaning can be also carried out chemically (exception). A recommended method is also included in appendix C. It should be remembered whether the arrangement should be in a filled or unfilled condition when it is out of order.

C.2.2 chemical cleaning

If a chemical cleaning is required, the following procedure is recommended:

  • a) chemical cleaning should be carried out by rinsing with certified products;
  • b) the system has to be completely rinsed and filled with water or without inhibitor, according to the requirements applicable for the facility;
  • c) if the whole system is not chemically cleaned at the same time, it is recommended to close the security stop valves in order to avoid that contaminates can originate from non-treated system parts.